Product Description
SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep ****************************** Attention, product canceled / successor product P320/P420 available! Please get in touch with your Siemens contact to determine the successor product ****************************** Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 1 to 60 mbar (0.4015 to 24.09 inH2O), max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection: 1/4-18 npt mounting thread: M10 Die-cast aluminium housing, process flange bolts stainless steel Standard design . Explosion protection EEx ia Electric connection and cable inlet: cable gland M20 x1.5 without visible digital indicator (digital display hidden, setting: mA) Sealing screw (1/4-18 npt) with valve in material of process flange Plate inscription english Test certificate according to standard IEC 60770-2 Functional safety SIL2. Devices suitable for use according to IEC 61508 and IEC 61511. Includes SIL conformity declaration. Range (linear characteristic) specify in plain text: Y01:... to ...mBar,kpa,mpa